The evolution of technical standards and the increasing awareness of the vulnerability of existing building heritage have shifted the focus of the engineering community from simple new-build design to the complex assessment of the safety of existing structures. In this context, the concept of structural robustness emerges as a fundamental parameter for determining a system's ability to withstand exceptional events or advanced states of degradation without undergoing collapse that is disproportionate to the triggering cause. This issue assumes critical importance in the case of reinforced concrete buildings constructed between the 1960s and 1970s, which, although designed according to the criteria of the time, now face the consequences of degenerative chemical-physical processes that compromise their original integrity. Evaluating the effect of localized degradation on robustness is therefore not just an academic exercise but an operational necessity to define maintenance and reinforcement strategies aimed at safeguarding public safety.
Structural robustness is commonly defined as the ability of a system not to suffer extensive damage following an initial local failure. This principle is based on the availability of alternative load paths that allow the structure to redistribute stresses from compromised components to those that remain intact. However, when discussing environmental degradation, such as the carbonation of concrete or the penetration of chloride ions, the damage does not manifest as an instantaneous event but as a slow and progressive process that gradually reduces the resistant section of the steel reinforcement and the bond strength between steel and concrete. This silent weakening can lead to a condition where the loss of a single load-bearing element, caused by reaching an ultimate limit state due to corrosion, triggers a chain-reaction collapse that the structure is no longer able to resist due to the loss of ductility and hyperstaticity.
In the study of a residential building taken as a reference, the analysis focuses on simulating scenarios where degradation acts specifically on critical pillars or structural nodes. The analyzed building exhibits the typical characteristics of reinforced concrete frame constructions, where regularity in plan and height should theoretically guarantee a good response to loads. However, the application of advanced calculation models, such as non-linear static and dynamic analyses, reveals that the presence of localized degradation drastically alters the overall behavior of the structure. The reduction in the diameter of the reinforcement bars, quantified through in-depth diagnostic investigations, leads not only to a decrease in the resisting moment of the sections but also to a modification of the hierarchy of strengths, making the beam-column nodes potential starting points for brittle failure mechanisms that the original design had not anticipated.
The methodological process adopted to assess robustness usually involves the virtual removal of a load-bearing element to observe the system's response. In a degraded structure, this analysis must be preceded by the correct characterization of the remaining materials. It is therefore essential to consider how corrosion is not uniform along the entire height of the pillar but often concentrates at the base or in the interface areas with the floors, where moisture can accumulate more easily. When a pillar loses its load-bearing capacity due to the corrosion of the longitudinal reinforcement and the failure of the stirrups, the structure must rely on the membrane effect of the slabs and the ability of the adjacent beams to work in tension and compression to transfer the load to the contiguous spans. However, if these elements also show signs of degradation, the robustness chain breaks, inevitably leading to the collapse of the affected portion of the building.
Parallel to the analysis of the resistant section, it is crucial to examine the role of ductility. A robust structure must possess a high capacity for deformation in the plastic range to dissipate energy and allow for load redistribution. The degradation of reinforced concrete acts directly against this property, making the steel more brittle and reducing the confinement provided by the concrete. In the checks conducted on the case study, it is observed that even a minimal loss of section in the transverse reinforcement can cause a sudden shear failure of the pillar, preventing the development of plastic hinges and effectively nullifying the structure's ability to activate those subsidiary resistance mechanisms that form the basis of the robustness concept. This scenario highlights how global safety depends non-linearly on the health of individual local components.
The analysis of the results obtained through numerical simulations emphasizes that existing civil buildings often show a marked sensitivity to the localization of damage. While the loss of a central pillar might be partially compensated by the collaboration of the surrounding frames thanks to the symmetry of the structure, the compromise of a corner or perimeter pillar proves to be extremely more dangerous. In these cases, the eccentricity of the load and the lack of structural continuity on one side drastically limit the possibilities for redistribution, making the structure vulnerable to overturning or instantaneous partial collapse. The research thus highlights that it is not sufficient to evaluate the overall safety of a building based on nominal loads, but it is imperative to integrate models that account for the evolution of degradation over time, defining a useful life cycle beyond which robustness falls below safe levels.
In conclusion, the case of the residential building analyzed clearly demonstrates that localized degradation represents a subtle threat to the robustness of reinforced concrete structures. The transition from a ductile and redundant structural behavior to a brittle and unstable one can occur without macroscopic warning signs if one does not intervene with constant and accurate monitoring. For professionals in the field, this implies the need to adopt a multidisciplinary approach that combines material diagnostics with advanced structural modeling. Only through a deep understanding of the interaction phenomena between the environment and the structure will it be possible to ensure that existing buildings continue to perform their protective function, resisting not only the design loads but also the unexpected and the inevitable passage of time.